Center for Nuclear Technology Assessment - BATAN
Email: igndjoko@batan.go.id
ABSTRACT
BORON DILUTION IN THE PRIMARY COOLANT INFLUENCE TO THE FUEL CHARACTERISTIC OF PIUS REACTOR. The influence of boron dilution in the primary coolant to the fuel characteristic of Pressurized Water Reactor (PWR) have been studied as a preliminary study of fuel characteristic of Process Inherent Ultimate Safety (PIUS) reactor. The focus of study are fuel bundle with several enrichment of U-235 from 2.4% until 3.4% using boron dilution concentration in the primary coolant are 150 ppm and 200 ppm. The calculation result of the fuel bundle which is set as a matrix of 17x17 element and the dimension is 30.294 cm x 30.294 cm using WIMS-D4 personal computer (PC) version, shows that the value of infinite multiplication factor of the fuel bundle which 2.4% enrichment in the primary coolant with 200 ppm boron concentration is 1.01672. In general, it is concluded that the fuel bundle which enrichment of 2.4% and the concentration of boron dilution of 200 ppm, the PIUS reactor could be achieve the critical or could be able to start up.
Keywords : Boron Dilution, Primary Coolant, Fuel Characteristic, WIMS-D4, Start Up Reactor.
Published : Journal "Pengkajian Sains dan Teknologi Nuklir", Vol.3, No.1, 1998, Pusat Pengkajian Teknologi Nuklir, BATAN, ISSN No. : 0852-8047